Problem:

Broktrout TR114 BRI card may not work correctly

Date: 2006/08/07
Produkt: FaxChange
Version: 6.0
Service pack: 6.0.36
Area: BrookTrout
Category: BUG

Problem description:

If you are using Brooktrout TR114 BRI card, it may not work correctly when installed firmware is older than 2.79. Error looks like this: from outside view all works fine, but card can not make a call anywhere, incoming calls aren't accepted (call is answered and hung up immediately).

Problem solution:

Install fimware 2.79 into the card. It can be found on installation CD from Faxchange version 6.0.36 in file support\Brooktrout\tr114\ForCustomersbri279andfaxfw219release.zip. Procedure:

  • stop all Faxchange services
  • unpack mentioned file
  • start command prompt and go to the folder where file was unpacked
  • run briconf -f brifw279.s
  • firmware configures card to point-to-multipoint mode, so if you are using point-to-point mode, you must switch card using briconf -p bri.txt command, where content of bri.txt file is the following:
    datalink ptp
    bearer 31kaudio
     
Now Faxchange will work correctly.

Other information:

--

Keywords:

 

FaxChange, Brooktrout, TR114, BRI, firmware